Shop Air System

Request from NADHack bill payers

It is very easy to leave the compressor on by accident when leaving the Hackspace. Please take extra care to ensure that the compressor is turned off before you leave.

Health and Safety Warning

The air system is surprisingly dangerous. The pressures and flow rates involved can cause major damage, including fatalities, if used irresponsibly.

Under no circumstance must any tool or equipment attached to the Hackspace air system be targeted at any person or their clothing. This includes using the air-dusters on clothing, skin, face, etc.

Eye protection must be worn whenever using any air tools.

Power up sequence

The air compressor needs to be pressurised before opening the valve to the air distribution system. This is because there are automatic drain valves on the water trap outlets which open at low pressure. If these valves are in the open position the compressor cannot generate enough airflow to close them.

This can be resolved by closing the outlet valve on the compressor. This allows pressure to build inside the compressor and, once 2 bar (30psi) of pressure has built the outlet valve can be safely opened. The automatic valves on the water traps should then immediately close.

To power up the system:

Power down sequence

Do not turn off the compressor at the wall The compressor pressure switch has a function to place the compressor piston at the right position when stopping the motor. For this function to work the compressor must be turned off using the pressure switch.

To power down the system: